CARDIO PULMONARY EXERCISE and STRESS TESTING

  1. Advanced Technology
  2. Transmural breathing decreases total test time and improves patient comfort Pressure-compensated flow effordt index Plenum technology reduces effects of ambient pressure fluctuations Perform gas dilution in box (optional) to compare with VTG for non-communicating gas volume Perform both breath holding and non-breath holding diffusing capacity Digital filtering temporally aligns thermal drift during quiet breathing RAW Kelvin-Sensing Mass Flow Sensor eliminates spurious electrical resistance artifact
  3. VTG and RAW Patient Comfort Display individual and composite tracings Adjustable quiet-breathing compensation
  4. Fast, All-in-One Testing Capabilities Complete all tests in 60-seconds (SVS ,RAW, VTG, and FVC) Capable of testing individual parameters separately
  5. Patient Comfort Large cabin accommodates adult or parent holding small child Quiet breathing technique more comfortable for some patients Rotating arm allows for testing outside cabin Full wheelchair accessability with wheelchair option
  6. User-friendly Software Set up software to perform tests in your of preference Multiple-study trending capability Easily share data with hospital information systems (including ADT) or physician reading stations. Logic Tree Option for user-defined, automated interpretation of data
  7. Compression-Free Flow Volume Loops For patient with airflow limitations (5), flowrates at specific lung volumes have been shown to be erroneous if volume is derived at the mouth only. Calculates the traditional Flow/Volume loop and simultaneously measures the Total Flow/Volume loop by the chest movement Excellent indicator of patient effort not discernable with traditional flow/volume loops
  8. Iso-Thermal Lung Volume Standard Ultimate quality assurance plethysmograph tool Produces know VTG using an isothermal vessel
  9. Applications : • Pulmonary function analysis • Cardio Pulmonary Exercise • Natritional Assessment • Respiratory Mechanics V max Specifications - Flow/Volume/Gas Measurements - Flow/Volume Type : Mass Flow Sensor with Kelvin-Sensing Range : 0-16 LPS Resolution : 0.0003@0.2 LPS 0.0012@2.0 LPS 0.0037@10 LPS 0.0061@16 LPS.003 LPS From 20-16 LPS Flow Accuracy : + 3% of reading or 0.25 LPS, whichever is greater, over the across range of 0.2 to 14 LPS Volume Accuracy : + 3% of reading or 0.050L, whichever is greater Resistance : + 1.5 cmH2O/LPS @12 LPS O2 Analyzer Type : Electrochemical Cell Range : 0-100% Resolution : 0.015% Accuracy : + 0.02% CO2, 0-10% Flash Multi-Gas* Type : Non-disperse infared, thermopile Range : 0-16% Resolution : 0.01% Accuracy : + 0.02% CO2, 0-10% Flash Multi-Gas *Type : Non-disperse infared, thermopile Range : 0-0.33% CO 0-0.33% CH4 0-0.33% C2H2 Resolution : 0.0005% CO 0.0005% CH4 0.0005% C2H2 Accuracy : + 0.003% CO + 0.003% CH4 + 0.003% C2H2 • Transducers